• CG-SK1(S) Single Humidity (Condensation) Controller

    One way condensation control:
    ① When the ambient humidity exceeds the condensation value, start the load;
    ② After starting the load, when the humidity drops to (condensation value return difference), turn off the load;
    ③ The condensation setting value is set before leaving the factory and cannot be modified by the user; ④ Manual/automatic control.

    More +
  • CG-S2K1(S) Dual Humidity (Condensation) Controller

    Two way condensation control:
    ① When the ambient humidity exceeds the condensation value, start the load;
    ② After starting the load, when the humidity drops to (condensation value return difference), turn off the load;
    ③ The condensation setting value is set before leaving the factory and cannot be modified by the user;
    ④ Manual/automatic control.

    More +
  • CG-WK(G) Single Channel Temperature Controller

    One way temperature control:
    ① The product is divided into ascending temperature type and descending temperature type, which are set before leaving the factory;
    ② The temperature setting value is set before leaving the factory and cannot be modified by the user;
    ③ Manual/automatic control.

    More +
  • CG-WSK(G) Temperature and Humidity (Condensation) Controller

    One way condensation control, one way temperature control (heating type):
    ① The condensation setting value is set before leaving the factory and cannot be modified by the user;
    ② The temperature setting value is set before leaving the factory and cannot be modified by the user;
    ③ Manual/automatic control.

    More +
  • CG-WK-P Temperature Controller

    One way temperature control:
    ① The product is divided into ascending temperature type and descending temperature type, which are set before leaving the factory;
    ② The temperature setting value is set by the user.

    More +
  • CG-WSK-P Temperature and Humidity (Condensation) Controller

    One way condensation control, one way temperature control:
    ① The product is divided into ascending temperature type and descending temperature type, which are set before leaving the factory;
    ② The condensation setting value is set before leaving the factory and cannot be modified by the user;
    ③ The temperature setting value is set by the user.

    More +
  • CG-WSK-ZXS Digital Display Temperature Controller

    One way condensation control, one way temperature control:
    ① Users can set their own heating and cooling modes;
    ② The setting value of condensation is set by the user; ③ The temperature setting value is set by the user;
    ④ Equipped with sensor error correction function (-20 ℃ ~ 20 ℃ );
    ⑤ Visually display the measured humidity.

    More +
  • CG-WSK-ZSX-Ⅱ Temperature and Humidity Controller

    Two way condensation control, two way temperature control:
    ① The product is divided into ascending temperature type and descending temperature type, which are set before leaving the factory;
    ② The condensation setting values of 88% RH and 93% RH can be set;
    ③ The temperature setting value is set before leaving the factory and cannot be modified by the user;
    ④ When the load is disconnected, there is a wire break alarm function (3A/AC250V);
    ⑤ Manual/automatic control, power on/off control.

    More +
  • CG-WSK- Ⅲ Temperature and Humidity Controller

    Two way condensation control, two way temperature control:
    ① The product is divided into ascending temperature type and descending temperature type, which are set before leaving the factory;
    ② The condensation setting values of 88% RH and 93% RH can be set;
    ③ The temperature setting value is set before leaving the factory and cannot be modified by the user;
    ④ When the load is disconnected, there is a wire break alarm function (3A/AC250V);
    ⑤ Manual/automatic control, power on/off control.

    More +
  • CG-WSK-ZSX-Ⅳ Temperature and Humidity Controller

    Two way condensation control, two way temperature control:
    ① The product is divided into ascending temperature type and descending temperature type, which are set before leaving the factory;
    ② The condensation setting values of 88% RH and 93% RH can be set;
    ③ The temperature setting value is set before leaving the factory and cannot be modified by the user;
    ④ When the load is disconnected, there is a wire break alarm function (3A/AC250V);
    ⑤ Manual/automatic control, power on/off control.

    More +
1